Heatmiser - UH4 Wiring Centre
Description
The Heatmiser UH4 can be used in conjunction with our mains voltage thermostats.
The UH4 is also ideally suited for underfloor heating but can also control a single zone of radiators.
- The UH4 provides central switching of up to 4 zone actuators
- Output for a hot water cylinder and the system boiler and pump.
- UH4 Dimensions 384x148x60mm
Installation
The UH4 can be mounted directly to a wall using four screws or alternatively, the unit can be DIN rail mounted.
When DIN Rail mounting, you first need to insert the two clips provided on the back of the UH4.
- On the back of the UH4, position the clip in the middle and slide down.
- Points A and B locate in the corresponding holes and lock into place.
- Locate the UH4 onto the DIN rail from the top.
- Pull the clip down and push the bottom of the UH4 onto the DIN rail.
- Releasing the clip will lock the UH4 in place on the DIN rail.
To remove the UH4, pull both clips down and remove from the DIN rail.